Model Selection Guide:
1. First, Based on operating voltage V (effective value) to decide needed dielectric strength Vp, see Table-1
Operating Voltage (V) |
220V |
380V |
500V |
800V |
Dielectric Strength (Vp) |
1.9kV |
3.1 kV |
4.5 kV |
6 kV |
|
Click Here to Download Catalog
|
|
2. Choose Voltage Ratio based on input power voltage and needed IGBT drive voltage
For example: When primary pulse is 15V, for reliable IGT drive, choose drive transformer with ratio 1:1 like
DRT801/101A, DRT801/111B or DRT802/101A and so on; if primary is 24-30V, choose the ones with ratio 2:1 like
DRT801/201A, DRT801/211B or DRT802/201A, etc.
|
|
3. Use product of volt-microsecond (∫udt
) and drive pulse frequency(Fp) to select models under the rule of the
∫udt is no bigger than the rated
∫udt of the DRT drive transformer at a specific Fp
For example: Given that the pulse frequency 20KHz, pulse voltage 15V and pulse
width 20μs, then
∫udt =15×20=300 μVs; Based on the rule of the given
∫udt (300 μVs) no larger than rated
∫udt of the DRT drive transformer at the Fp(20KHz), in this
case we choose DRT802 series; If given Fp 50KHz, pulse voltage 24V, pulse width
10μs, the
∫udt =24×10=240μVs, then we can choose DRT801 series.
|
|
4. For users who don't know the parameters of drive pulse, use table below to determine models.
IGBT Spec. (A) |
Below 100A |
100A~400A |
Above 100A |
|
Recommended |
DRT801/101A DRT801/201A DRT801/301A DRT801/111B DRT801/211B DRT801/311B |
DRT802/101A DRT802/201A DRT802/301A DRT802/111B DRT802/211B DRT802/311B |
DRT803/101A DRT803/201A DRT803/301A DRT803/111B DRT803/211B DRT803/311B |
|
 |
|